Quantcast
Channel: THWACK: Popular Discussions - Kiwi CatTools
Viewing all 21331 articles
Browse latest View live

Enterasys Securestack Backup failing

$
0
0

Hello,

 

i'm trying to backup my Enterasys Securestack B5 switch with CatTools 3.11 but it fails. It gets stuck as you can see in the debug below :

 

 

<NEWSESSION CatTools 3.11.2 25/07/2017 16:30:50>

<PROTOCOL=SSH2>

<DEVICE TYPE=Enterasys.Securestack>

<ACTIVITY TYPE=Device.Backup.Running Config>

<ACTIVITY SCRIPT=C:\CatTools3\Scripts\Client.Device.Backup.Running Config.txt>

<USERS NAME FOR DEVICE=switch-nsi-03>

<C OK 16:30:51>

<R-16:30:51>[13][10][13][10]Enterasys B5 [13][10]Command Line Interface [13][10][13][10]Enterasys Networks, Inc. [13][10]9 Northeastern Boulevard[13][10]Salem, NH 03079 U.S.A. [13][10][13][10]Phone: +1 603 952 5000 [13][10]E-mail: support@enterasys.com [13][10]WWW: http://www.enterasys.com [13][10][13][10](c) Copyright Enterasys Networks, Inc. 2013[13][10][13][10]

<R-16:30:51>Chassis Serial Number:      10201410905A[13][10]Chassis Firmware Revision:  06.71.03.0025[13][10][13][10]Last successful login : MON JUL 24 13:25:34 2017[13][10]Failed login attempts since last login : 0[13][10][13][10]Stack Enterasys backbone ASTEN NSI Shelter Relecq[13][10]switch-nsi-03(su)->

<W-16:30:51>[13]

<R-16:30:51>[13][10]switch-nsi-03(su)->

<W-16:30:51>show config all

<R-16:30:51>s

<R-16:30:51>how config all

<W-16:30:52>[13]

<R-16:30:52>[13][10][10]begin[13][10]![13][10]#***** ALL (DEFAULT and NON-DEFAULT) CONFIGURATION *****[13][10]![13][10]![13][10]# Firmware Revision:  06.71.03.0025[13][10]![13][10]#ip[13][10]set ip protocol none[13][10]set ip address 10.143.0.244 mask 255.255.255.0 gateway 10.143.0.160[13][10]![13][10][13][10]#security[13][10]set security profile normal[13][10]![13][10][13][10]#system[13][10]set switch member 1 5 [13][10]set switch member 2 5 [13][10]set switch description 1 "Enterasys Networks, Inc. B5 -- Model B5K125-24"[13][10]set switch description 2 "Enterasys Networks, Inc. B5 -- Model B5K125-24"[13][10]set system name "Stack NSI Enterasys backbone ASTEN NSI"[13][10]set system location "Asten NSI Gouesnou salle serveurs"[13][10]set system contact "Stephane Saintilan"[13][10]set system fault-bias default trap disable [13][10]set system password-resetbutton enable[13][10]set system temperature syslog disable trap disable overtemp-threshold 100[13][10]set system utilization threshold 800[13][10]set system password aging disable warning-period 20 grace-period 0 grace-limit 0 history 0 length 7 min-required-chars uppercase 0 lowercase 0 numeric 0 special 0 require-at-creation no allow-duplicates yes substring-match-len 0 allow-repeating-chars yes change-first-login no change-frequency 0 [13][10]set system login admin super-user enable  password :3b29b72c5860b3d2b382dd7aea6611563f9aad71e7ca7a1a4667b40bbe07d727b57c0d30cf3af20233: local-only no aging 0 simultaneous-logins 0 [13][10]set system login asten super-

...

(A lot more lines i deleted)

...

<R-10:58:05>[13][10]set vlanauthorization egress untagged ge.2.6[13][10]set vlanauthorization egress untagged ge.2.7[13][10]set vlanauthorization egress untagged ge.2.8[13][10]set vlanauthorization egress untagged ge.2.9[13][10]set vlanauthorization egress untagged ge.2.10[13][10]set vlanauthorization egress untagged ge.2.11[13][10]set vlanauthorization egress untagged ge.2.12[13][10]set vlanauthorization egress untagged ge.2.13[13][10]set vlanauthorization egress untagged ge.2.14[13][10]set vlanauthorization egress untagged ge.2.15[13][10]set vlanauthorization egress untagged ge.2.16[13][10]set vlanauthorization egress untagged ge.2.17[13][10]set vlanauthorization egress untagged ge.2.18[13][10]set vlanauthorization egress untagged ge.2.19[13][10]set vlanauthorization egress untagged ge.2.20[13][10]set vlanauthorization egress untagged ge.2.21[13][10]set vlanauthorization egress untagged ge.2.22[13][10]set vlanauthorization egress untagged ge.2.23[13][10]set vlanauthorization egress untagged ge.2.24[13][10]set vlanauthorization egress untagged tg.2.25[13][10]set vlanauthorization egress untagged tg.2.26[13][10]set vlanauthorization egress untagged lag.0.1[13][10]set vlanauthorization egress untagged lag.0.2[13][10]set vlanauthorization egress untagged lag.0.3[13][10]set vlanauthorization egress untagged lag.0.4[13][10]set vlanauthorization egress untagged lag.0.5[13][10]set vlanauthorization egress untagged lag.0.6[13][10]![13][10][13][10]#webview[13][10]set webview disable[13][10]![13][10][13][10]#width[13][10]set width 79 default[13][10]![13][10]end[13][10][10][13][10]switch-nsi-03(su)->

 

================================================================================

WFMDRetVal=1 Waiting for: "--More-- <space> next page, <cr> one line, <q> quit"

WFMDRetVal=2 Waiting for: "% Invalid input detected at"

WFMDRetVal=3 Waiting for: "% Incomplete command"

WFMDRetVal=4 Waiting for: "(y/n) ["

WFMDRetVal=5 Waiting for: "File transfer operation completed successfully"

WFMDRetVal=18 Waiting for: "switch-nsi-03(su)-->"

 

 

 

The Report result :

 

It seems the backup script doesn't know what to do with the show config all.

I did a "show config all" manually from my switch and i didn't get as much informations than in the debug file. There is way less informations.

 

The Device type is spot on, Enterasys Securestack B5 :

 

Can you help me get past this error ?

 

 

thanks in advance.


Backup Extreme Networks Switch Failing

$
0
0

Hi,

 

i'm having issues backing up my Extreme Networks B5 switch with Device.Backup.Running.Config script.

Here is the debug file :

 

 

<NEWSESSION CatTools 3.11.2 26/07/2017 11:37:19>

<PROTOCOL=SSH2>

<DEVICE TYPE=Extreme.Switch.General>

<ACTIVITY TYPE=Device.Backup.Running Config>

<ACTIVITY SCRIPT=C:\CatTools3\Scripts\Client.Device.Backup.Running Config.txt>

<USERS NAME FOR DEVICE=switch-nsi-intersite-relecq>

<C OK 11:37:20>

<R-11:37:20>[13][10][13][10]Extreme B5 [13][10]Command Line Interface [13][10][13][10]Extreme Networks, Inc. [13][10]9 Northeastern Boulevard[13][10]Salem, NH 03079 U.S.A. [13][10][13][10]Phone: +1 603 952 5000 [13][10]E-mail: support@enterasys.com [13][10]WWW: http://www.extremenetworks.com [13][10][13][10](c) Copyright Extreme Networks, Inc. 2014[13][10][13][10]

<R-11:37:20>Chassis Serial Number:      15060732916E[13][10]Chassis Firmware Revision:  06.71.05.0008[13][10][13][10]Last successful login : WED JUL 26 11:24:37 2017[13][10]Failed login attempts since last login : 0[13][10][13][10]Stack Enterasys Baie Schelter Relecq intersite vers Gouesnou[13][10]switch-nsi-intersite-relecq(su)->

<W-11:37:22>[13]

<R-11:37:22>[13][10]switch-nsi-intersite-relecq(su)->

 

================================================================================

WFMDRetVal=1 Waiting for: " #"

WFMDRetVal=2 Waiting for: " >"

WFMDBuffer="[13][10]switch-nsi-intersite-relecq(su)->"

================================================================================

 

 

Device configuration :

 

 

Info Log reports :

 

 

Can you help me figure out how to get past this ?

Do i have to change the prompt options ?

 

thanks in advance

Aborting command entry due to command error

$
0
0

I have a problem with a device in configuration mode.

 

I try to apply 2 commands and one is applied ok, the 2nd one does not seem to work.

 

Here's the sequence:

Waiting for command prompt

Waiting for an echo of system-view command

Waiting for an echo of super command

Waiting for an echo of acl number 2003

[Then a 33 second pause]

Stopping Activity.

 

Here are the 2 commands

acl number 2003

rule 110 permit source 10.209.127.174 0

 

Here's what it looks like when I paste it into the device

[sysname-1]acl number 2003

Info: When the ACL that is referenced by SACL is modified, the SACL will be dynamically updated. During the update, these SACL will become invalid temporarily.

[sysname-1]rule 110 permit source 10.209.127.174 0

 

Thanks for your help

HP Procurve configuration backup using SSH problem

$
0
0

Hello,

We have an HP Procurve J4903A Switch 2824 and it is integrated with RADIUS Server for authentication.
We are using Cat Tools 3.4 demo version and tried to configure the switch for configuraton backup using Method SSH2.
And using Device.Backup.Running Config  Type and SSH Username/Password are supplied. When Run the backup it shows the errors:
"Did not receive expected prompt when entering enable mode", and "Aborting: Unable to enter enable mode".

Do anybody faced this issue with SSH? Please help me to solve this problem.

Regards,

Achu

UltiDev Cassini Web Server 2.1.0.3

Backup config.csv for a RuggedCom device

$
0
0

I am trying to find a way to schedule the backup of a ruggedcom RS900G using CatTools.  We have a banner configured and once you log in, the device prompts you to press enter.  I cant seem to find a way to send <enter> to the device.  That seems to be the hold up right now.

At the end of the day I need the program to SSH in, and copy the file to a directory like my cisco switches.

Device.Backup.Running Config not comparing files

$
0
0

I have been running CatTools 3.4 Free on an XP machine for some time and found it brilliant.

I've recently replaced this machine with a Win 7 x64 machine and installed CatTools 3.6 Free.  Everything is working correctly except for the compare running configs which tells me that there is no change even when there is.  This is occurring for several Cisco and Juniper models and they worked fine under 3.4 (which unfortunately I don't have anymore).

I dont' know if it's a cause or a result but the Dated Configs folder remains empty and does not have any history of the changed configs either.  The version of the running config in the Config directory is always correct (ie it updates correctly when the activity runs) it's just the comparison and Dated Config that fails (or never occurs).

Please help, this is exactly what I used CatTools for.  I've tried a fresh install and created new activities to no avail.

Thanks,
J

Backup running config for OpenBSD PF Firewall

$
0
0

Hello,

 

I've been trying to get Kiwi Cattools to download the PF config file from an OpenBSD system. I have managed to get Kiwi Cattools to login to the machine via ssh but then it throws this cryptic error to the log:

 

Login results = VTY: Failed, Enable: N/A, HostID: N/A

 

Just hoping someone can guide me in the right direction. The help files say that the debug mode will help troubleshoot the problem. I'm not sure what to look for in the log. This is the output I get when I try the test login command:

 

<NEWSESSION CatTools 3.5.0 7/10/2012 7:05:58 PM>

<PROTOCOL=SSH2>

<DEVICE TYPE=OpenBSD.PF.Firewall>

<ACTIVITY TYPE=Device.ConnectivityTest.Login>

<ACTIVITY SCRIPT=C:\Program Files\CatTools3\Scripts\Client.Device.ConnectivityTest.Login.txt>

<USERS NAME FOR DEVICE=DSFW>

<C OK 7:05:58 PM><R-7:05:58 PM>Last login: Tue Jul 10 18:09:13 2012 from 10.100.101.248[13][13][10]OpenBSD 5.1 (GENERIC.MP) #207: Sun Feb 12 09:42:14 MST 2012[13][10][13][10]Welcome to OpenBSD: The proactively secure Unix-like operating system.[13][10][13][10]Please use the sendbug(1) utility to report bugs in the system.[13][10]Before reporting a bug, please try to reproduce it with the latest[13][10]version of the code.  With bug reports, please try to ensure that[13][10]enough information to reproduce the problem is enclosed, and if a[13][10]known fix for it exists, include that as well.[13][10][13][10][13][27][3g        [27]H        [27]H        [27]H        [27]H        [27]H        [27]H        [27]H        [27]H        [27]H[13][13]<W-7:05:58 PM>[13]<R-7:05:58 PM>[13][10]<R-7:05:59 PM># [13][13][10]# <D 7:05:59 PM>

<SCRIPT VALUES>

<HOSTNAME="">

<PROMPT VTY="">

<PROMPT ENABLE="">

<PROMPT CONFIG="">

 

On the line that thats out '<C OK', that includes the login banner that the system gives so I know it's getting logged in. After login, the prompt is just a "#" and I also see that on that line twice towards the end. These are the variables I have set in the script file for that device:

 

Private Const DEVICE_STANDARDPROMPT = "#"

Private Const DEVICE_PRIVILEGEDPROMPT = "#"

Private Const DEVICE_CONFIGPROMPT = "#"

 

Is it having trouble picking up on the # prompt?

 

I appreciate any help. Thanks!


How to edit multiple device in a row ?

$
0
0

Dear Community,

 

Due to new security measures, we have to change our authentication method for fewer devices in Kiwi CatTools.

 

How could we do that ?

 

We already tried to select multiple devices than "Edit" but it's only editing the first one selected

and to export the database to edit as flat file but we can't figure it out how to include new credentials as KiwiCrypt format.

 

Thank you for your help.

 

Cheers !

Backing up F5 BIGIP UCS archive

$
0
0

Does anybody know if there is a way to backup the UCS archive on the BIGIP's, I think the current template in CatTools only backs up the config file. You really need the UCS archive to be able to restore devices properly. 

Many thanks

Mark

Switch faied to connect (10061)

$
0
0

Hi

 

I have only recently started a new position and am new to Kiwi Cat tools which this organisation uses, (Used Solar Winds before)

 

Any help or assistance would be greatfully appreciated. 

 

Just installed a new Cisco 3650 switch and Cisco 4331 Router at a new site and trying to configure Kiwi to back this up.

 

Keep getting the error 'failed to connect to x.x,x,x Reason (10061) The requested connection has been refused by the remote host on the switch, router works fine and backs up on Kiwi.

 

I have checked the config on the 3650 switch and it has the same log in details as the 4331 router at the site that is working on Kiwi

 

The Kiwi version that I am using is VER 3.11.2 Enterprise

 

The switch version is 03.06.04.E

 

I have also been asked to look at and resolve all the back up errors or Kiwi, Is there a downloadable Kiwi pdf that someone can post a link to and also a list of error codes

 

Thank you in advance.

Script for HP/H3C Switches

$
0
0

Hi!

 

I'm trying to backup the config of our new HP (H3C) Switches (5120, 5800, 10500). The script I created out of the Custom.Template is not working. The prompt of the switches is "<SWITCHNAME>", not "SWITCHNAME>" as in Ciscos IOS. So the script returns the error "Did not receive expected prompt when entering Enable mode".

Has anybody managed to create a script that works with the HP H3C switches?

 

Regards, lls71

Backup Extreme Summit switches using TFTP commands

$
0
0

Hi, We have just installed some extreme switches and currently
it is backing up using model X450-24X running the show configuration command.

We are wanting to run the following below command and wondered whether this
would be possible if we had a variations file and running a TFTP server on
server where cat tools is installed.

 

tftp put x.x.x.x vr "VR-Default"primary.cfg **Saved file name***.cfg

 

The above command makes it easier to restore configs if we were to have issues.

 

We tried running Device.Backup.TFTP activity but it currently only supports Cisco Devices.

 

 

Thanks

Enterasys Securestack Backup failing

$
0
0

Hello,

 

i'm trying to backup my Enterasys Securestack B5 switch with CatTools 3.11 but it fails. It gets stuck as you can see in the debug below :

 

 

<NEWSESSION CatTools 3.11.2 25/07/2017 16:30:50>

<PROTOCOL=SSH2>

<DEVICE TYPE=Enterasys.Securestack>

<ACTIVITY TYPE=Device.Backup.Running Config>

<ACTIVITY SCRIPT=C:\CatTools3\Scripts\Client.Device.Backup.Running Config.txt>

<USERS NAME FOR DEVICE=switch-nsi-03>

<C OK 16:30:51>

<R-16:30:51>[13][10][13][10]Enterasys B5 [13][10]Command Line Interface [13][10][13][10]Enterasys Networks, Inc. [13][10]9 Northeastern Boulevard[13][10]Salem, NH 03079 U.S.A. [13][10][13][10]Phone: +1 603 952 5000 [13][10]E-mail: support@enterasys.com [13][10]WWW: http://www.enterasys.com [13][10][13][10](c) Copyright Enterasys Networks, Inc. 2013[13][10][13][10]

<R-16:30:51>Chassis Serial Number:      10201410905A[13][10]Chassis Firmware Revision:  06.71.03.0025[13][10][13][10]Last successful login : MON JUL 24 13:25:34 2017[13][10]Failed login attempts since last login : 0[13][10][13][10]Stack Enterasys backbone ASTEN NSI Shelter Relecq[13][10]switch-nsi-03(su)->

<W-16:30:51>[13]

<R-16:30:51>[13][10]switch-nsi-03(su)->

<W-16:30:51>show config all

<R-16:30:51>s

<R-16:30:51>how config all

<W-16:30:52>[13]

<R-16:30:52>[13][10][10]begin[13][10]![13][10]#***** ALL (DEFAULT and NON-DEFAULT) CONFIGURATION *****[13][10]![13][10]![13][10]# Firmware Revision:  06.71.03.0025[13][10]![13][10]#ip[13][10]set ip protocol none[13][10]set ip address 10.143.0.244 mask 255.255.255.0 gateway 10.143.0.160[13][10]![13][10][13][10]#security[13][10]set security profile normal[13][10]![13][10][13][10]#system[13][10]set switch member 1 5 [13][10]set switch member 2 5 [13][10]set switch description 1 "Enterasys Networks, Inc. B5 -- Model B5K125-24"[13][10]set switch description 2 "Enterasys Networks, Inc. B5 -- Model B5K125-24"[13][10]set system name "Stack NSI Enterasys backbone ASTEN NSI"[13][10]set system location "Asten NSI Gouesnou salle serveurs"[13][10]set system contact "Stephane Saintilan"[13][10]set system fault-bias default trap disable [13][10]set system password-resetbutton enable[13][10]set system temperature syslog disable trap disable overtemp-threshold 100[13][10]set system utilization threshold 800[13][10]set system password aging disable warning-period 20 grace-period 0 grace-limit 0 history 0 length 7 min-required-chars uppercase 0 lowercase 0 numeric 0 special 0 require-at-creation no allow-duplicates yes substring-match-len 0 allow-repeating-chars yes change-first-login no change-frequency 0 [13][10]set system login admin super-user enable  password :3b29b72c5860b3d2b382dd7aea6611563f9aad71e7ca7a1a4667b40bbe07d727b57c0d30cf3af20233: local-only no aging 0 simultaneous-logins 0 [13][10]set system login asten super-

...

(A lot more lines i deleted)

...

<R-10:58:05>[13][10]set vlanauthorization egress untagged ge.2.6[13][10]set vlanauthorization egress untagged ge.2.7[13][10]set vlanauthorization egress untagged ge.2.8[13][10]set vlanauthorization egress untagged ge.2.9[13][10]set vlanauthorization egress untagged ge.2.10[13][10]set vlanauthorization egress untagged ge.2.11[13][10]set vlanauthorization egress untagged ge.2.12[13][10]set vlanauthorization egress untagged ge.2.13[13][10]set vlanauthorization egress untagged ge.2.14[13][10]set vlanauthorization egress untagged ge.2.15[13][10]set vlanauthorization egress untagged ge.2.16[13][10]set vlanauthorization egress untagged ge.2.17[13][10]set vlanauthorization egress untagged ge.2.18[13][10]set vlanauthorization egress untagged ge.2.19[13][10]set vlanauthorization egress untagged ge.2.20[13][10]set vlanauthorization egress untagged ge.2.21[13][10]set vlanauthorization egress untagged ge.2.22[13][10]set vlanauthorization egress untagged ge.2.23[13][10]set vlanauthorization egress untagged ge.2.24[13][10]set vlanauthorization egress untagged tg.2.25[13][10]set vlanauthorization egress untagged tg.2.26[13][10]set vlanauthorization egress untagged lag.0.1[13][10]set vlanauthorization egress untagged lag.0.2[13][10]set vlanauthorization egress untagged lag.0.3[13][10]set vlanauthorization egress untagged lag.0.4[13][10]set vlanauthorization egress untagged lag.0.5[13][10]set vlanauthorization egress untagged lag.0.6[13][10]![13][10][13][10]#webview[13][10]set webview disable[13][10]![13][10][13][10]#width[13][10]set width 79 default[13][10]![13][10]end[13][10][10][13][10]switch-nsi-03(su)->

 

================================================================================

WFMDRetVal=1 Waiting for: "--More-- <space> next page, <cr> one line, <q> quit"

WFMDRetVal=2 Waiting for: "% Invalid input detected at"

WFMDRetVal=3 Waiting for: "% Incomplete command"

WFMDRetVal=4 Waiting for: "(y/n) ["

WFMDRetVal=5 Waiting for: "File transfer operation completed successfully"

WFMDRetVal=18 Waiting for: "switch-nsi-03(su)-->"

 

 

 

The Report result :

 

It seems the backup script doesn't know what to do with the show config all.

I did a "show config all" manually from my switch and i didn't get as much informations than in the debug file. There is way less informations.

 

The Device type is spot on, Enterasys Securestack B5 :

 

Can you help me get past this error ?

 

 

thanks in advance.

Backup Extreme Networks Switch Failing

$
0
0

Hi,

 

i'm having issues backing up my Extreme Networks B5 switch with Device.Backup.Running.Config script.

Here is the debug file :

 

 

<NEWSESSION CatTools 3.11.2 26/07/2017 11:37:19>

<PROTOCOL=SSH2>

<DEVICE TYPE=Extreme.Switch.General>

<ACTIVITY TYPE=Device.Backup.Running Config>

<ACTIVITY SCRIPT=C:\CatTools3\Scripts\Client.Device.Backup.Running Config.txt>

<USERS NAME FOR DEVICE=switch-nsi-intersite-relecq>

<C OK 11:37:20>

<R-11:37:20>[13][10][13][10]Extreme B5 [13][10]Command Line Interface [13][10][13][10]Extreme Networks, Inc. [13][10]9 Northeastern Boulevard[13][10]Salem, NH 03079 U.S.A. [13][10][13][10]Phone: +1 603 952 5000 [13][10]E-mail: support@enterasys.com [13][10]WWW: http://www.extremenetworks.com [13][10][13][10](c) Copyright Extreme Networks, Inc. 2014[13][10][13][10]

<R-11:37:20>Chassis Serial Number:      15060732916E[13][10]Chassis Firmware Revision:  06.71.05.0008[13][10][13][10]Last successful login : WED JUL 26 11:24:37 2017[13][10]Failed login attempts since last login : 0[13][10][13][10]Stack Enterasys Baie Schelter Relecq intersite vers Gouesnou[13][10]switch-nsi-intersite-relecq(su)->

<W-11:37:22>[13]

<R-11:37:22>[13][10]switch-nsi-intersite-relecq(su)->

 

================================================================================

WFMDRetVal=1 Waiting for: " #"

WFMDRetVal=2 Waiting for: " >"

WFMDBuffer="[13][10]switch-nsi-intersite-relecq(su)->"

================================================================================

 

 

Device configuration :

 

 

Info Log reports :

 

 

Can you help me figure out how to get past this ?

Do i have to change the prompt options ?

 

thanks in advance


Device.Backup.Running Config not comparing files

$
0
0

I have been running CatTools 3.4 Free on an XP machine for some time and found it brilliant.

I've recently replaced this machine with a Win 7 x64 machine and installed CatTools 3.6 Free.  Everything is working correctly except for the compare running configs which tells me that there is no change even when there is.  This is occurring for several Cisco and Juniper models and they worked fine under 3.4 (which unfortunately I don't have anymore).

I dont' know if it's a cause or a result but the Dated Configs folder remains empty and does not have any history of the changed configs either.  The version of the running config in the Config directory is always correct (ie it updates correctly when the activity runs) it's just the comparison and Dated Config that fails (or never occurs).

Please help, this is exactly what I used CatTools for.  I've tried a fresh install and created new activities to no avail.

Thanks,
J

Latest Cattools on SG300 switches?

$
0
0

Can the latest RC of Cattools perform config backups on Cisco Small Business SG300 switches? We are having a hard time getting this working over SSH with TACACS.

failed to receive config prompt

$
0
0

when using kiwi to add config i get error failed to receive config prompt after entering command: crypto key generate rsa

 

obviously the switch is waiting for an input. ive tried adding the input on the next line but it doesnt seem to work.

 

how do i enter the command using kiwi

ASA backup issue

$
0
0

Hello,

 

I am trying to backup an ASA config using Device.Backup.TFTP and when I run it I receive this error:

 


Device Type: Cisco.Firewall.ASA has not yet had this functionality added. Skipping this device.

 

I was wondering if anyone knew what would be causing this error? My guess is that something needs to be added to the Cisco.Firewall.ASA script to give it functionality (please correct me if I am wrong) and then it should start working. If this is correct, can someone please guide me through the process of getting this started.

 

Thank you,

 

Johnathan

F5.BigIP.TMSH Changes Pending

$
0
0

Whenever I use the F5.BigIP.TMSH Device Type and have CatTools login into a Device I end up with a (Changes Pending) when the device was (In Sync) before. I thought maybe it had something to do with the Activity I wrote but I just have the script login and logout and I get a Changes Pending. This is problematic. Anyone else experience the same problem.

Viewing all 21331 articles