Im trying to use CatTools to update bulk Avaya switches (Model:4850GTS-PWR) passwords for read only and read write user accounts.
In the options window I am entering something like this:
username RO password
************
************
username RW password
***********
***********
When I run CatTools it fails on and the debug looks like this (it looks like commands are running twice?, Maybe the devices are configured wrong?):
Note: This was ran only for the RO password.
================================================================================
WFDRetVal=0. Waiting for: "ctrl-y to begin"
WFDBuffer="[13][13][10]owcc-m-wc#[13][13][10]#nortelswitch"
================================================================================
<W-2:12:08 PM>[13]
<R-2:12:08 PM>[13][13][10]
<R-2:12:09 PM>nortelswitch#
<W-2:12:09 PM>terminal length 0
<R-2:12:09 PM>terminal length 0
<W-2:12:09 PM>[13]
<R-2:12:09 PM>[13][13][10]
<R-2:12:09 PM>nortelswitch#
<W-2:12:09 PM>[13]
<R-2:12:09 PM>[13][13][10]
<R-2:12:09 PM>nortelswitch#
<W-2:12:09 PM>[13]
<R-2:12:09 PM>[13][13][10]
<R-2:12:09 PM>nortelswitch#
<W-2:12:10 PM>configure terminal
<R-2:12:10 PM>configure terminal
<W-2:12:10 PM>[13]
<R-2:12:10 PM>[13][13][10]Enter configuration commands, one per line. End with CNTL/Z.[13][13][10]
<R-2:12:10 PM>nortelswitch(config)#
<W-2:12:10 PM>[13]
<R-2:12:10 PM>[13][13][10]
<R-2:12:11 PM>nortelswitch(config)#
<W-2:12:11 PM>username RO password
<R-2:12:11 PM>username RO password
<W-2:12:11 PM>[13]
<R-2:12:11 PM>[13][13][10]
<R-2:12:11 PM>nortelswitch(config)#
<W-2:12:11 PM>***password***
<R-2:12:11 PM>***password***
<W-2:12:11 PM>[13]
<R-2:12:11 PM>[13][13][10] ^[13][13][10]% Invalid input detected at '^' marker.[13][13][10]
<R-2:12:12 PM>nortelswitch(config)#
<W-2:12:14 PM>[26]
<R-2:12:14 PM>^Z[13][13][10][13][13][10]
<R-2:12:14 PM>nortelswitch#
<W-2:12:14 PM>[13]
<R-2:12:14 PM>[13][13][10]
<R-2:12:14 PM>nortelswitch#
<W-2:12:14 PM>[13]
<R-2:12:14 PM>[13][13][10]
<R-2:12:14 PM>nortelswitch#
<W-2:12:15 PM>disable
<R-2:12:15 PM>disable
<W-2:12:15 PM>[13]
<R-2:12:15 PM>[13][13][10]
<R-2:12:15 PM>nortelswitch>
<W-2:12:15 PM>[13]
<R-2:12:15 PM>[13][13][10]
<R-2:12:15 PM>nortelswitch>
<W-2:12:15 PM>terminal length 24
<R-2:12:15 PM>terminal length 24
<W-2:12:15 PM>[13]
<R-2:12:15 PM>[13][13][10]
<R-2:12:16 PM>nortelswitch>
<W-2:12:16 PM>exit[13]
<R-2:12:16 PM>exit[13][13][10]
<R-2:12:16 PM>
<D 2:12:16 PM>
-----------------------------------------------------------------
Any suggestions to clean this up and get it running would be much appreciated. Not sure what I've overlooked during the setup...
Thanks